Differential Pressure Transmitter 984

    Categories Pressure, AIR

    The differential pressure transmitters of the 984 series are used to measure differential pressure, overpressure and vacuum. They provide up to 8 pressure ranges and 2 output signals, which are easily selectable by jumper or rotary selector switch.

    For an optimum adaptation to the application, the transmitter can be switched between various pressure ranges. The factory setting is the most sensitive range. For the series 984M and 984A the less sensitive second range will be selected by simply removing a jumper. For the series 984Q the available eight ranges can be selected by a rotary selector switch.

    Brand : Beck GmbH

    • Description
    • Attachment

      Applications

    • Building automation and air conditioning systems
    • Overpressure measurement in clean rooms and laboratories
    • Measurement of constant pressure in VAV applications
    • Dynamic filter and ventilator monitoring

    984M with manual offset calibration

      Setting ranges

    • Depending on type between -100 Pa und 1 bar

      Temperature range

    • Working and storage temperature from -20°C to +70°C

      Process connection

    • Hose connection with 4 / 6 mm outer diameter

      Supply voltage

    • 18 to 30 VDC

      Output signal switchable (only with 3-wire type):

    • 0 – 10 V
    • 4 – 20 mA

      Electrical connection

    • Plug-in terminals for wires and strands up to 1.5 mm²

      Protection class

    • IP54 acc. to EN 60529 with protection cap
    • IP00 without protection cap

    984A with automatic offset calibration

      Setting ranges

    • Depending on type between -100 Pa und 500 mbar

      Temperature range

    • Working and storage temperature from -10°C to +50°C

      Process connection

    • Hose connection with 4 / 6 mm outer diameter

      Supply voltage

    • 18 to 30 VDC

      Output signal switchable (only with 3-wire type):

    • 0 – 10 V
    • 4 – 20 mA

      Electrical connection

    • Plug-in terminals for wires and strands up to 1.5 mm²

      Protection class

    • IP54 acc. to EN 60529 with protection cap
    • IP00 without protection cap

    984Q with automatic offset calibration

      Setting ranges

    • Depending on type between -500 Pa und 2.500 Pa

      Temperature range

    • Working and storage temperature from -10°C to +50°C

      Process connection

    • Hose connection with 4 / 6 mm outer diameter

      Supply voltage

    • 18 to 30 VDC

      Output signal switchable (only with 3-wire type):

    • 0 – 10 V
    • 4 – 20 mA

      Electrical connection

    • Plug-in terminals for wires and strands up to 1.5 mm²

      Protection class

    • IP54 acc. to EN 60529 with protection cap
    • IP00 without protection cap

    Data Sheet

    Download

    Manual

    Download