Pressure Calibration Device KAL 100

    Categories Pressure, Low Pressure Generator & Calibrators

    Pressure calibration device with integrated pressure generator for stationary and mobile applications

    Brand : Halstrup-walcher GmbH

    • Description
    • Attachment

      Special features

    • High level of accuracy and long-term stability through automatic zero-point calibration
    • Available for 4 measurement ranges
    • Simple menu navigation for unit conversion, setting calibration points and setting the measurement range
    • Menu navigation in German, English, Italian, French and Spanish
    • Generation of positive and negative differential pressures
    • Can be calibrated
    • Easy to operate and produce calibration curves via optional USB port and PC

    The KAL 100 calibration device combines a pressure transmitter and pressure gauge. These can be used to test and calibrate pressure sensors and other pressure gauges for low pressures both quickly and easily. The desired pressure is indicated on the digital display and pressure is generated quickly and precisely through the use of a closed loop, thereby eliminating the need for an external pressure generator.

      Options

    • The KAL 100 can also be fitted with a USB port (optional). This allows testing protocols to be transferred simply to the PC.
    • Available with a power supply and a measuring input for external test objects. No additional power adapters or measuring instruments required for the test object.
    • Available with lithium-ion rechargeable battery.
    • Available with a calibration certificate according to DKD-R 6-1.
    • Also available with carrying bag (standard) or transport case.

      Measurement ranges

    • 0 .. 100 / 0 .. 200 / 0 .. 500 Pa
    • 0 .. 1 / 0 .. 2 / 0 .. 5 / 0 .. 10 / 0 .. 20 / 0 .. 50 / 0 .. 100 kPa
    • ± 100 / ± 200 / ± 500 Pa
    • ± 1 / ± 2 / ± 5 / ± 10 / ± 20 / ± 50 / -80 .. 100 kPa

      Measurement Accuracy

    • ± 0.2 % FS for measurement ranges > 0 .. 200 Pa / ± 200 Pa
    • ± 0.5 % FS for measurement ranges ≤ 0 .. 200 Pa / ± 200 Pa

      Data interface

    • USB + measurement input for test object

      Display

    • Alphanumeric display with 2 x 20 characters, backlighting

      Input / power supply

    • 0 .. 10 V, 0 .. 20 mA, Accuracy: 0.2 % FS

      Available unit settings

    • Pa, kPa, mmHg , mmH2O , inH2O

      Power supply

    • 85 .. 264 VAC
    • 85 .. 264 VAC and rechargeable lithium ion battery

    Data sheet KAL 100/200

    Download

    Instruction manual KAL 100/200 Series 3

    Download