CD ATEX

    Categories ATEX / Flameproof Product, ATEX Membrane Level Switch

    Intended Use

    Membrane level indicator to be used to control normally the medium or minimum level of bulk solids in silos or vessels. The models are certificated for use in potentially explosive Dust and Gas atmospheres as well as in hybride mixtures (Dust + Gas) hazardous areas.

    These controllers consist of a switch actuated by a membrane and it is recommended for dusty and powdery, granulated and grainy bulk goods like dust, flour, grain, sand, plastic, etc. with an easy flow and a bulk density from 0.3 to 2.5 t/m3.

    Brand : Filsa

    • Description
    Name Membrane level indicator
    Type CD-II-B3 – ref: 2201-A-002
    CD-AII-B1 – ref: 2201-A-006
    CD-AII-B5 – ref: 2201-A-004
    Certification
    B1 Dust ATEX II 1/2D Ex ta/tb IIIC T83 °C Da/Db
    B3 Dust ATEX II 1/3D Ex ta/tc IIIC T63 °C Da/Dc
    B5 Gas+Dust ATEX II 1/2D Ex ta/tb IIIC T83 °C Da/Db
    ATEX 2G Ex ib IIC T6 Gb
    Density of the product 0,3 t/m3 – 2,5 t/m3
    Ambient pressure Atmospherical
    Maximum pressure +1 bar
    Cable entry M20x1,5
    Maximum voltage 250 V AC
    Contact function 1 NO + 1 NC
    Capacity of the contact
    CD (B1 and B3) 4 A / 250 V AC (for resistive loads) For inductive or capacitive loads reduce at 50%
    CD (B5) Uo < 30 V DC; Ii < 100 mA
    Ambient temperature
    CD -20° C – +60° C
    CD (B1 and B5) -25° C – +80° C
    Protection According to DIN EN60529
    CD: IP65
    CD (B1 and B5): IP66
    Weight CD: 0,49 Kg
    CD (B1 and B5): 0,95 Kg
    Sensitivity 150 – 2.000 g adjustable
    Materials
    Housing CD (B3): Glass reinforced Polyester

    CD (B1 y B5): Aluminum
    Membrane Stainless Steel 1.4301
    Mounting ring and screws Stainless Steel 1.4301
    Cable gland CD (B3): Polyamide
    CD (B1 and B5): Niquel-plated Brass