Freely adjustable as tank level indicator & linearisation up to 30 support points (via free software)
Configuration via display & possibility for software-supported visualisation and configuration
Very quick compensation of temperature jump
Wetting parts made of high-grade steel 1.4435
Housing made of high-grade steel 1.4404
Pressure screw for free positioning
Individual measuring range adjustment
Smallest measuring range 100 mbar
Turndown 4:1
Fourfold overload
Galvanically isolated electronics
Insulation voltage: 300V
Totally front-flush membrane
FDA, EHEDG-conformal
Technical Specifications
Accuracy according to IEC 60770: 0,1 % of adjusted measuring value
Long-term stable
Short-circuit-proof + reverse voltage protected
Functional ranges (temperature): Medium to be measured (permanent):-20 °C to 110 °C Medium to be measured max. (1/2 h) up to 140 °C High-Temperature-Version permanent up to 180 °C
Protection class up to IP 69 K (execution-dependently)