Indicator / panel meter STR551 is designed for process acquisition and retransmission via analogue output.
Brand : Pixsys
Categories Monitor, Digital Process Indicator
Indicator / panel meter STR551 is designed for process acquisition and retransmission via analogue output.
Brand : Pixsys
The monochrome OLED graphical display supports process trend displays with programmable sampling time and bar-graph representation with thresholds typically used for level, flow and dosage measurements.
Analogue input is configurable by parameter for a wide range of temperature sensors and process signals in mA and volts. Linearization is customizable up to a maximum of 16 points, useful on irregularly profiled tanks.
Process-related mathematical functions such as Totalizer and Sum are also implemented.
Connectivity is provided by standard RS485 with Modbus RTU/Slave protocol.
For maximum flexibility of use, there is also a choice of horizontal or vertical installation. User can program the device using the intuitive interface with multi-language text menus of the MyPixsys App thanks to integrated NFC communication.
Dimensions | 96x48 (Front panel) x 48 mm (1/8Din) |
Material | Box: polycarbonate V0. Front cover: silicone rubber |
Weight | Approx. 165 g |
Sealing | Front panel: IP54, Box and terminal blocks: IP20 |
Operating conditions | Temperature 0..45 °C, humidity 35..95 RH%, max altitude 2000m |
Certifications | CE, UL |
Ordering Codes | STR551-12ABC-T128R |
---|---|
Power supply | 24..230 V AC / DC ±15% 50/60 Hz - galvanic isolation 2,5KV |
Power consumption | 8 Watt/Va |
Display | 2.42" monochrome (yellow) OLED graphic display, 128 x 64 |
Analogue inputs |
1 x Ris. 16bit, programmable for thermocouples K, S, R, J, T, E, N, B (automatic compensation of the cold junction -25..85°C, Toll. @25°±0,2% F.S. ±1 digit F.S.), Thermoresistances PT100, PT500, PT1000, Ni100, Ni120, PTC 1K, NTC 10K (β 3435K e β3694K), NTC 2252 (β3976K) , process signals 0..1/5/10 V (50000 points), 0/4..20mA (40000 points), 0..60 mV (25000 points), Potentiometer 1..150 KΩ (50000 points). Impedance: 0-10 V: Ri>110 KΩ 0-20 mA: Ri<5 Ω 0-40 mV: Ri>1 MΩ |
Sampling time | Programmable up to 4,1 mS (frequency up to 242 Hz) |
Digital input | 2x PNP |
Analogue outputs | 1x 0..10V (60000 points) 1x 0/4..20mA (60000 points) |
Digital Outputs | - |
Auxiliary Output | 12/24 VDC - 25mA max for sensor power supply |
Relais Outputs | 2x 2 A - 250 V AC resistive load |
Serial communication | RS485 (1200..115200 Baud) galvanically isolated |
USB | 1x micro USB for programming via PC with LabSoftView |
Alarms regulation | ON - OFF with hysteresis |
Alarm Mode | Absolute / Threshold, Band with instantaneous/delayed/retentive/by digital input activation, Sensor failure / Activation by serial line |
Sum Function | Sum different process measurements over time By digital input or by keyboard |
Totalizer Function | Visualisation of instant process value and total value since last reset |
Latch-on Function | Semi-automatic setting of limits/ calibration values for analogue inputs |
Graphic Function | Trend display with time base settable from 1sec to 3600sec total 4K memory words |
Measure Unit Visualization | Selection of different measuring units |
Multilingual Menu | English/Italian/German/French/Spanish |
Analogue retransmission | Retransmission of process values / setpoints to analogue outputs |
Software parameter | Memory Card, software LABSOFTVIEW, codici EASY-UP - Programming via APP (NFC) "MyPixsys" for |
Configuration | Android and iOS devices |
Software Protections | Command setpoints / alarms - Password for parameter access |
Communication Protocols | Modbus RTU |
STR551-12ABC-T128R | DOUBLE SETPOINT INDICATOR 96X48 RFID OLED 128x64 -2 RL-RS485-24/230 |