Differential Pressure Transmitter 985

    Categories Pressure, AIR

    The differential pressure transmitters of the 985 series are used to measure differential pressure, overpressure and vacuum. They provide up to 8 pressure ranges and 2 output signals, which are easily selectable by jumper or rotary selector switch. Monitoring of gaseous, non-combustible and non-aggressive media.

    Brand : Beck GmbH

    • Description
    • Attachment

      Applications

    • Building automation and air conditioning systems
    • Overpressure measurement in clean rooms and laboratories
    • Measurement of constant pressure in VAV applications
    • Dynamic filter and ventilator monitoring

    985M 2-wire with manual offset calibration

      Setting Ranges

    • Depending on type between -100 Pa and 1 bar

      Temperature Range

    • Working and storage temperature from –20°C to +70°C

      Process Connection

    • Hose connection with 4 / 6 mm outer diameter

      Supply Voltage

    • 18 to 30 VDC

      Output Signal

    • 4 – 20 mA

      Electrical Connection

    • Plug-in terminals for wires and strands up to 1.5 mm2 or circular connectors M12 / 4-pole

      Protection Class

    • IP65 acc. to EN 60529

    985M 3-wire with automatic offset calibration

      Setting Ranges

    • Depending on type between -100 Pa and 1 bar

      Temperature Range

    • Working and storage temperature from –20°C to +70°C

      Process Connection

    • Hose connection with 4 / 6 mm outer diameter

      Supply Voltage

    • 18 to 30 VDC

      Output Signal

    • 0 – 10 V
    • 4 – 20 mA

      Electrical Connection

    • Plug-in terminals for wires and strands up to 1.5 mm2 or circular connectors M12 / 4-pole

      Protection Class

    • IP65 acc. to EN 60529

    985A 3-wire with automatic offset calibration

      Setting Ranges

    • Depending on type between -100 Pa and 1 bar

      Temperature Range

    • Working and storage temperature from –10°C to +50°C

      Process Connection

    • Hose connection with 4 / 6 mm outer diameter

      Supply Voltage

    • 18 to 30 VDC

      Output Signal

    • 0 – 10 V
    • 4 – 20 mA

      Electrical Connection

    • Plug-in terminals for wires and strands up to 1.5 mm2 or circular connectors M12 / 4-pole

      Protection Class

    • IP65 acc. to EN 60529

    985Q 3-wire with automatic offset calibration

      Setting Ranges

    • Depending on type between -100 Pa and 1 bar

      Temperature Range

    • Working and storage temperature from –10°C to +50°C

      Process Connection

    • Hose connection with 4 / 6 mm outer diameter

      Supply Voltage

    • 18 to 30 VDC

      Output Signal

    • 0 – 10 V
    • 4 – 20 mA

      Electrical Connection

    • Plug-in terminals for wires and strands up to 1.5 mm2 or circular connectors M12 / 4-pole

      Protection Class

    • IP65 acc. to EN 60529