Categories Control, Process PID Controller
- Universal analogue input (TC, RTD, mA, V)
- Multiple alarm modes
- Dynamic smart Tune
- Optional RS485 isolated
Brand : Pixsys
Categories Control, Process PID Controller
Brand : Pixsys
| BOX | 32x74 (front panel) x 53 mm |
|---|---|
| POWER SUPPLY |
24..230 V AC / DC ±15% 50/60 Hz - galvanic isolation 2,5KV (code -ABC) 12..24 V AC/DC ±10% 50/60 Hz - galvanic isolation 2,5KV (code -AD) |
| POWER CONSUMPTION | 5 W |
| DISPLAY | 3 digits 0,59" white |
| OPERATING CONDITIONS | Temperature 0-45 °C, humidity 35..95 RH% |
| MATERIAL | Box: PC UL94V2 self-extinguishing, front panel: PC UL94V2 |
| WEIGHT | Approx. 120 g |
| SEALING | IP65 (front panel) IP20 (box and terminal blocks) |
| QUICK SET-UP OPTIONS | Memory Card, software LABSOFTVIEW |
| "MyPixsys" APP |
Device setup via NFC for Android smartphone (Google Play). Via BT-NFC (2000.35.099) for iOS smartphone (App Store). |
| 1 CONFIGURABLE | Res. 16 bit, selectable for TC type K, S, R, J, T (automatic compensation of cold junction -25..85°C, ±0,2% F.S. ±1 digit F.S.), thermoresistances PT100, PT500, PT1000, Ni100, Ni120, PTC1K, NTC10K (B3435K), process signals 0..10 V (50000 points), 0/4..20 mA (40000 points), potentiometer 1..150 KΩ (50000 points) |
|---|---|
| SAMPLING TIME | Programmable up to 2,1 ms (frequency up to 470 Hz) |
| 1/2 RELAYS | Q1 Relay 8 A - 250 V AC resistive charge - Q2 Relay 5 A - 250 V AC resistive charge |
|---|---|
| 1 DIGITAL OUTPUT | 8 VDC - 20 mA (codes ABC) - 12..35 VDC - 30 mA (code AD) |
| 1 AUXILIARY | 8 VDC - 20 mA (codes ABC) - 12..35 VDC - 30 mA (code AD) for sensor supply |
| SERIAL COMMUNICATION | RS485 Modbus RTU - Slave (4800..115200 baud code T) |
| CONTROL ALGORITHMS | ON - OFF with hysteresis, P, PI, P.I.D., P.D. time proportioned |
|---|---|
| TUNING | Manual or automatic |
| DATA PROTECTION | Lock of control / alarm setpoint / Access to parameters by password |
| ALARM MODES | Absolute / Threshold, Band, High / Low deviation. Alarm with optional manual reset. Loop Break Alarm function |
| AUTO / MANUAL FUNCTION | Output percentage command also with automatic change in case of sensor failure |
| DOUBLE P.I.D. | Heating / Cooling P.I.D. |
| SOFT-START | Rising gradient expressed as Degrees / Hour or fixed output percentage |
| Code | Description |
|---|---|
| ATR124-AD | 1 Analogue Input + 2 Relays / Digital Output 12..24 V AC/DC |
| ATR124-AD-T | 1 Analogue Input + 1 Relay / Digital Output 12..24 V AC/DC + RS485 |
| ATR124-ABC | 1 Analogue Input + 2 Relays + 1 Digital Output 24..230 V AC/DC |