    Categories Liquid & Gas Analysis, Turbidity Sensor

    • Reliable concentration measurement using optical measuring process
    • Infrared light pulsing beams scattering method
    • AISI 316 and black rigid PVC sensor body (optional only AISI 316 or only PVC)
    • No mechanically moving parts
    • Measured value pre-processing in sensor resulting in low signal transmission sensitivity
    • Immediate installation and easy manteinance

      APPLICATIONS

    • Measure of turbidity in pure and drinkable water
    • Measure of turbidity in primary, industrial, recirculating water
    • Description
    • Attachment

    TECHNICAL DATA

    Materials Black PVC and AISI 316 Body • Special Glass Optics with oleophobic treatment • NBR and Silicon OR
    Thread 1” GAS
    Measuring ranges 0–1000 NTU
    0–4000 NTU
    Measuring method 90° Scattered light
    Calibration method 1-point for scale with formazin standard solution
    Resolution 0.01 NTU range 0–1000 NTU
    0.01 NTU range 0–4000 NTU
    Accuracy ±2% at measuring point range 0–1000 NTU
    ±5% at measuring point range 0–4000 NTU
    Repeatability ±5 NTU range 0–1000 NTU
    ±20 NTU range 0–4000 NTU
    Response T90 < 60s
    Working temperature 0–40 °C
    Max working pressure 4 bar
    Max absorption 3W
    Mechanical protection IP68 Sensor + cable
    Cable 10m integral
    Power supply 12…24Vdc
    Outputs RS485 (4–20mA optional)

    Data sheet

    Download