HVAC Transmitters
Pressure, airflow, temperature, humidity, CO2 and air quality transmitters for building automation.
An HVAC transmitter converts a physical measurement, such as pressure, airflow, temperature, humidity or CO2, into a standard signal the BMS can use. This page brings together every measurement Produal and Beck cover for building automation, so you can find the right transmitter by what you need to measure rather than by brand or model.
Browse by type
Transmitters Subcategories
Temperature Transmitters
6 productsHumidity Transmitters
5 productsCO2 Sensors
6 productsPM / VOC / CO Sensors
3 productsDifferential Pressure Transmitters for Air
9 productsAirflow Transmitters
2 productsAir Velocity Transmitters
2 productsAirflow Probes
1 productDifferential Pressure Transmitters for Water
1 product35 Products · Transmitters

2-wire Differential Pressure Transmitter DPT-2W

Air Flow And Velocity Transmitter

Air Velocity Transmitter

Airflow Transmitter DPT-Flow-MOD

Airflow volume probe FloXact

CO2 Transmitter RT-CO2

CO2 Transmitter RTX-CO2

Cable Temperature Transmitter TEKY4 LL

DPT-FLOW WITH FLAMEPROOF ENCLOSURE


DPT-R8 WITH FLAMEPROOF ENCLOSURE
HVAC differential pressure transmitter for air, flameproof enclosure, 8 selectable ranges





Differential Pressure Transmitter 988 - Liquid

Differential Pressure Transmitter DPT-Dual-MOD
Selection guide
HVAC Transmitters Guide
Choose an HVAC transmitter by measurement
- Differential pressure across filters, fans or rooms: the DP Transmitters for AHUs cover clean rooms, filters and general air handling.
- Differential pressure in water circuits: DP Transmitters for Water control pumps and monitor strainers and heat exchangers.
- Fan or duct air volume: the Airflow Transmitters calculate volume flow from differential pressure, paired with the Airflow Probes for an averaged duct reading.
- Confirming fans and ducts deliver design airflow: the Air Velocity Transmitters prove fans and alarm on low airflow.
- Room, duct, pipe or outdoor temperature: the Temperature Transmitters send readings to the BMS for heating, cooling and ventilation control.
- Humidity for comfort or process control: the Humidity Transmitters cover clean rooms, data centres and general buildings.
- Demand-controlled ventilation: the CO2 Sensors adjust fresh air to occupancy to save energy.
- Pollutants beyond CO2: the VOC and Air Quality Sensors pick up gases from materials and activity that CO2 alone misses.
Controllers built into some transmitters
- DPT-Ctrl: part of the DP Transmitters for AHUs range, keeps fans, VAV systems and dampers at a constant pressure or flow.
- RTX-CO2: part of the CO2 Sensors range, has a built-in P/PI controller for spaces without a full BMS.
- Benefit: this can simplify a small installation that doesn't justify a full building management system.
A closing note on outputs: 0 to 10 V is common in building automation, 4 to 20 mA suits long cables, and many Produal models also offer Modbus RTU, so check what your controller accepts before ordering, since getting this wrong at design stage is a common cause of rework on site.
FAQ
Common questions
Which output should I choose for my BMS?
0 to 10 V is common in building automation and suits shorter cable runs. 4 to 20 mA is better over long cables because it resists interference and voltage drop. Many Produal models also offer Modbus RTU, so check what your controller or BMS input card actually accepts before ordering.
Can one transmitter measure several values at once?
Yes. For example, the DPT-Dual-MOD has two pressure sensors in one housing, and the RTX room transmitters combine temperature with CO2, humidity or VOC depending on the model, so you can cover several readings without fitting separate devices.
Are HVAC transmitters field-configurable?
Most Produal transmitters have field-selectable ranges and outputs, set by jumpers, an on-device menu, or a commissioning app such as MyProdual or ML-SER, so an installer can match the device to the job on site rather than ordering a fixed configuration.
How do I pick the right transmitter for building automation?
Start with what you need to measure: differential pressure, airflow, temperature, humidity or air quality. Then narrow by mounting location such as room, duct or outdoor, and finally by the output and any extras your BMS needs, such as Modbus or a display.
Do any HVAC transmitters have hazardous-area versions?
Yes. The DPT-R8 differential pressure transmitter and the DPT-Flow airflow transmitter are both available with a flameproof enclosure, for HVAC applications such as dust collector or bag filter systems in areas where standard electronics aren't permitted.
Need help?
Can't find what you need?
Our team helps you select the right transmitters products for your application. Request a quote or discuss your requirements.
Expert product guidance
Tailored selection of transmitters instruments
Custom solutions
Instruments customized for your specific industrial setup
Trusted global brands
Full warranty and official documentation support