EXstatic 312

hygienic process connections

Static probe housing for permanent installation of Ø12mm/120mm-sensors on tanks or pipelines by hygienic process connections. The probe housings are very easy to install and can be delivered with or without a sensor protection cage. The sensors used, especially glass sensors are very well protected against mechanical influences.

Your advantages

  • Designed according to hygienic criteria
  • Surface finish Ra<0,78 or Ra<0,37
  • Stainless steel AISI 316L / 1.4404
  • EPDM sealings with FDA and USP VI approval
  • Process connections according to EHEDG / 3A
  • Optional sensor protection cage
  • Up to 10 bar and 140 °C
  • Protection cap for cable connection

Brand : Exner

Description

Specifications

Process pressure:0…10 bar
Process temperature:-10…140 °C
Material:1.4404 / 316L
Surface:Ra<0,78 or Ra<0,37
Sealing material:EPDM / FDA / USP VI or FPM (Viton)
Material cable guard:PA6.6 GF30
Certificates:material, surface, sealing material
Option:with or without protection cage
Sensors:120 mm Ø12 PG13,5
Process connections:Varivent N, Neumo BioControl D50

EXstatic 312