Description
Applications :
- Wastewater technology
- liquid level measurement
- pump control
- medical technology
- and many more
Technical Data :
- Setting ranges:
Typ Factory-set switching points between Maximum positive working pressure
Standard/extended901.1x Ex 5 mbar and 200 mbar
200 mbar and 1.000 mbar0,5 / 4 bar
1 / 4 bar901.41Ex 500 mbar and 3.000 mbar 10 bar 901.51Ex 1,0 bar and 12 bar 25 bar 901.2x Ex -5 mbar and -200 mbar
-200 mbar and -900 mbar0,5 / 4 bar
1 / 4 bar901.30 Ex 5 mbar and 50 mbar 100 mbar
- Temperature range:
Temperature of media and ambient temperature from -20°C to 85°C
Storage temperature: -40° C bis +85° C
- Diaphragm material:
Depending on media NBR, Silicone, FKM (Viton®), EPDM. For 901.30 Silicone, others upon request.
- Pressure connection:
Material: PA, PVDF, Brass, Stainless steel
Hose nipple: 5,0mm, 6,5mm, 10,0mm
Thread: M10x1, G1/8, G1/4, G1/2
- Electrical rating:
24 VDC/100 mA
30 VDC/45 mA
- Electrical connection:
AMP flat plug 6.3 x 0.8 mm according to DIN 46244 or push-on screw terminals
- Protection class:
IP 54 (with cover 6371)
- Arrangement of contacts: