Description
Applications :
- Wastewater technology
- liquid level measurement
- pump control
- medical technology
- and many more
Technical Data :
- Setting ranges:
Type Factory-set switching points between Maximum positive working pressure
Standard/extended901.1x 5 mbar and 200 mbar
200 mbar and 1.000 mbar0,5 / 4 bar
1 / 4 bar901.41 500 mbar and 3.000 mbar 10 bar* 901.51 1,0 bar and 12 bar 25 bar 901.2x -5 mbar and -200 mbar
-200 mbar and -900 mbar0,5 / 4 bar
1 / 4 bar901.30 5 mbar and 50 mbar 100 mbar *For pressure connections made of plastic, the maximum permissible working pressure is 7 bar! - Temperature range:
Ambient temperature from –20°C to 85°C
Temperature of media up to 85°C or 130°C depending on material of pressure connection and diaphragm.
- Diaphragm material:
Depending on media NBR, Silicone, FKM (Viton®), EPDM. For 901.30 Silicone, others upon request.
- Pressure connection:
Material: PA, PVDF, PPS, Brass, Stainless steel
Hose nipple: 5,0mm, 6,5mm, 10,0mm
Thread: M10x1, G1/8, G1/4, G1/2
- Electrical rating:
Specification of the maximum values for ohmic load.
AgNi-contact:
6(1,5) A/250 VAC
2 A/24 VDC
Gilded contact:
100 mA/24 VAC
30 mA/24 VDC
On request AgNi contacts up to 10 A / 250 VAC can also be supplied.
- Electrical connection:
AMP flat plug 6.3 x 0.8 mm according to DIN 46244
- Protection class:
IP44 / IP54 / IP65 depending on the used protection cap
- Arrangement of contacts: