Vacuum Pressure switch 901 Prescal® adjustable

Vacuum Pressure switch 901 Prescal® adjustable

Adjustable pressure switch monitoring overpressure, vacuum or differential pressure of liquid and gaseous – also aggressive – media.

The pressure switch uses a scaled adjustment knob to enable the adjustment of trip and reset pressure without the use of a screwdriver.

Mounting in any position, to be specified for settings below 100 mbar.

Brand : Beck

Description

Applications : 

  • Wastewater technology
  • liquid level measurement
  • pump control
  • medical technology
  • and many more

 

Technical Data : 

  • Setting ranges:
    TypeSetting range for upper switching point betweenMaximum positive working pressure
    Standard/extended
    Maximum negative working pressure
    Standard/extended
    901.615 and 20 mbar0,5/4 bar–/–1 bar
    901.6210 and 50 mbar0,5/4 bar–/–1 bar
    901.6325 and 100 mbar0,5/4 bar–/–1 bar
    901.6450 and 250 mbar1/4 bar–/–1 bar
    901.65100 and 500 mbar1/4 bar–/–1 bar
    901.66250 and 1.000 mbar10 bar–1 bar
    901.67500 and 1.500 mbar10 bar–1 bar
    901.681.000 and 3.000 mbar10 bar–1 bar
    901.911,0 and 6,0 bar25 bar–1 bar
    901.924,0 and 9,0 bar25 bar–1 bar
    901.937,0 and 12,0 bar25 bar–1 bar
    901.71– 5 and – 20 mbar0,5/4 bar–1 bar
    901.72– 10 and – 50 mbar0,5/4 bar–1 bar
    901.73– 25 and – 100 mbar0,5/4 bar–1 bar
    901.74– 50 and – 125 mbar0,5/4 bar–1 bar
    901.75– 75 and – 200 mbar1/4 bar–1 bar
    901.76– 100 and – 300 mbar1/4 bar–1 bar
    901.77– 200 and – 500 mbar1/4 bar–1 bar
    901.78– 300 and – 700 mbar1/4 bar–1 bar
    901.815 and 20 mbar (differential pressure)100 mbar–100 mbar
    901.8210 and 50 mbar (differential pressure)100 mbar–100 mbar

 

  • Temperature range:
    Ambient temperature from –20°C to 85°C
    Temperature of media up to 85°C or 130°C depending on material of pressure connection and diaphragm.

 

  • Diaphragm material:
    Depending on media NBR, Silicone, FKM (Viton®), EPDM. For 901.8x Silicone, others upon request.

 

  • Pressure connection:
    Material: PA, PVDF, PPS, Brass, Stainless steel
    Hose nipple: 5,0mm, 6,5mm, 10,0mm
    Thread: M10x1, G1/8, G1/4, G1/2

 

  • Electrical rating:
    Specification of the maximum values ​​for ohmic load.
    AgNi-contact:
    6(1,5) A/250 VAC
    2 A/24 VDC
    Gilded contact:
    100 mA/24 VAC
    30 mA/24 VDC
    On request AgNi contacts up to 10 A / 250 VAC can also be supplied.

 

  • Electrical connection:
    AMP flat plug 6.3 x 0.8 mm according to DIN 46244

 

  • Protection class:
    IP44 / IP54 / IP65 depending on the used protection cap

 

  • Arrangement of contacts:

Data Sheet

Download

Manual

Download
Parshvi Technology